BHCVN - ALUMINUM ALLOYS

Product Identification

Product ID:ALUMINUM ALLOYS
MSDS Date:04/04/1989
FSC:5610
NIIN:01-012-3430
MSDS Number: BHCVN

Responsible Party
ALUMINUM COMPANY OF AMERICA
1501 ALCOA BUILDING
PITTSBURGH, PA 15219
US

Emergency Phone: 412-553-4001

Info Phone: 412-553-2881

Cage: 8B995

Contractor
ALUMINUM COMPANY OF AMERICA
PITTSBURGH, PA 15219 US

Telephone: 412-553-4001

Cage: 8B995

Ingredients

MANGANESE (SARA III)

CAS: 7439-96-5

RTECS: OO9275000

Fraction By Weight: 0.5-1.0%

OSHA PEL (C) 5 MG/M3 DUST

ACGIH TLV: 5 MG/M3 DUST 9293


CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: .05-0.2%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


IRON

CAS: 7439-89-6

RTECS: NO4565500


ALUMINUM (SARA III)

CAS: 7429-90-5

RTECS: BD0330000

Fraction By Weight: 60-100%

OSHA PEL 15MG/M3 DUST/5 FUME

ACGIH TLV: 10MG/M3 DUST; 9192

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALUMINUM SHOULD BE TREATED AS A
NUISANCE DUST IN MOST OPERATIONS. THIS NSN (A PLATE) DOES NOT
PRESENT EVEN THAT HAZARD.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:NONE EXPECTED TO OCCUR
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:IF ANY IRRITATION OCCURS, PERSISTS, OR IS SEVERE, SEE A
DOCTOR.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE, EXCEPT DO
NOT USE HALOGENATED EXTINGUISHING AGENTS ON CHIPS OR POWDERS.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:REACTS WITH ACIDS OR ALKALIS TO LIBERATE
HYDROGEN AN EXPLOSIVE GAS.

Accidental Release

Spill Release Procedures:SWEEP OR PICK UP.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:NO SPECIAL HANDLING OR STORAGE
REQUIREMENTS.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR FOR DUST IF PEL/TLV OF NUISANCE DUST IS EXCEEDED.
Ventilation:NOT NORMALLY REQUIRED.
Protective Gloves:TO PROTECT FROM CUTS, BURNS, ETC.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE PRACTICE.
Supplemental Safety and Health
MFR SUPPLIES MANY STANDARD ALUMINUM ALLOYS COVERED UNDER THIS MSDS.
FOR FORMULATION ANY OTHERS, SEE ASTM SPECS, OR ALCOA SPECS.

Chemical Properties

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:900-1200F
Spec Gravity:2.63-3.12
Solubility in Water:NONE
Appearance and Odor:SOLID METAL PLATE, NO ODOR
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS, ACIDS, ALKALIS, (IF ALUMINUM IS POWDERED, HALOGENATED
HYDROCARBONS)
Stability Condition to Avoid:EXCESSIVE HEAT
Hazardous Decomposition Products:REACTION WITH ACIDS OR ALKALIS
LIBERATES HYDROGEN, AN EXPLOSIVE GAS.

Disposal

Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
IF NOT RECOVERABLE SELL AS SCRAP OR DISPOSE AS ORDINARY REFUSE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.